MoistureMeterD Compact publications (217)

Lymphedema (103)

Diagnosis of upper quadrant lymphedema secondary to cancer: clinical practice guideline from the Oncology Section of the American Physical Therapy Association - 2017

K Levenhagen, C Davies, M Perdomo, K Ryans… – Physical …, 2017 – academic.oup.com

MoistureMeterD Compact, VapoMeter

… Additionally, 3 of the tape measurements for patients with head and neck (ear to ear; circumferential measurement of upper neck and lower neck) correlated with Moisture Meter D (MMD…

Manual lymphatic drainage with or without fluoroscopy guidance did not substantially improve the effect of decongestive lymphatic therapy in people with … - 2022

T De Vrieze, N Gebruers, I Nevelsteen, S Fieuws… – Journal of …, 2022 – Elsevier

MoistureMeterD Compact, VapoMeter

… an absolute excess volume difference, these numbers represent a range between –70 and 90 ml, which are not clinically relevant changes in the volume difference (ie, this is a small …

Imaging of interstitial fluid in skin and subcutaneous tissue using dual-frequency ultrasonography before and immediately after lymph drainage in breast cancer … - 2013

M Dai, M Katayama, J Sugama, M Okuwa… – J Tsuruma Health Sci …, 2013 – researchgate.net

MoistureMeterD Compact, VapoMeter

… Skin moisture was measured using a Moisture Meter D (Delfin Technologies, Kuopio, … The key limitation to the present study was considered to be the small number of subjects. In …

The effect of adjuvant radiotherapy on skin biophysical properties in patients with breast cancer at risk for breast lymphedema: A prospective study - 2023

A Tuğral, M Akyol, Y Bakar – Clinical Physiology and Functional …, 2023 – Wiley Online Library

MoistureMeterD Compact, VapoMeter

… Local tissue water percentage (as measured TDC) of the ipsilateral and contralateral sites were assessed with Moisture MeterD ™ (Delfin Technologies, Kuopio, Finland) at pre-RT and …

Correlation between clinical assessment and lymphofluoroscopy in patients with breast cancer-related lymphedema: a study of concurrent validity - 2020

S Thomis, L Dams, I Fourneau, T De Vrieze… – Lymphatic Research …, 2020 – liebertpub.com

MoistureMeterD Compact, VapoMeter

… Water content A vertical pressure is performed with the MoistureMeterD Compact ® (Delfin) to … This degree of reflection/water content can be read on the display of the MoistureMeterD. …

Two-year follow-up of temporal changes of breast edema after breast cancer treatment with surgery and radiation evaluated by tissue dielectric constant (TDC) - 2015

K Johansson, MH Darkeh… – The European …, 2015 – lymphoedemaeducation.com.au

MoistureMeterD Compact, VapoMeter

… ected and contralateral sides using the MoistureMeterD (Delfin Technologies Ltd, Finland). The … This might be due to a small number of patients with ALNB and small number of patients …

Experimental and analytical comparisons of tissue dielectric constant (TDC) and bioimpedance spectroscopy (BIS) in assessment of early arm lymphedema in breast … - 2015

T Lahtinen, J Seppälä, T Viren… – Lymphatic research and …, 2015 – liebertpub.com

MoistureMeterD Compact, VapoMeter

… -sectional area (blood component not illustrated due to its small size), (b) in percentage the … Lahtinen has acted as a research and development manager to Delfin Technologies Ltd. …

Five-year cumulative incidence of axillary web syndrome and comparison in upper extremity movement, function, pain, and lymphedema in survivors of breast cancer … - 2022

L Koehler, A Day, D Hunter, A Blaes, T Haddad… – Archives of Physical …, 2022 – Elsevier

MoistureMeterD Compact, VapoMeter

… Technologies, b which measured local tissue water bilaterally on the trunk at a location 8 cm below the axillary fold. The MoisturemeterD … under the MoisturemeterD transducer head. …

Relation between early disturbance of lymphatic transport visualized with lymphofluoroscopy and other clinical assessment methods in patients with breast cancer - 2022

S Thomis, N Devoogdt, T De Vrieze, B Bechter-Hugl… – Clinical breast …, 2022 – Elsevier

MoistureMeterD Compact, VapoMeter

… Moisture meter D Compact (Delfin Technologies) Seven locations on the arm (Figure 3). Placement probe on the reference point with gentle pressure. PWC operated side compared to …

Intrarater reliability of tonometry and bioimpedance spectroscopy to measure tissue compressibility and extracellular fluid in the legs of healthy young people in … - 2017

J Douglass, P Graves, S Gordon – Lymphatic Research and Biology, 2017 – liebertpub.com

MoistureMeterD Compact, VapoMeter

… Delfin Technologies, Finland, provided the SkinFibroMeter on loan to JCU for the purposes of the study. Delfin Technologies retain no editorial or publication rights in regard to this …

Other (114)

Clinical Practice Guideline - 2017

K Levenhagen, C Davies, M Perdomo, K Ryans… – Physical …, 2017 – academia.edu

MoistureMeterD Compact, VapoMeter

… Additionally, 3 of the tape measurements for patients with head and neck (ear to ear; circumferential measurement of upper neck and lower neck) correlated with Moisture Meter D (MMD…

The effect of advanced glycation end-products on the development of skin-tears: a cross-sectional study comparing onset and non-onset groups in skin-tear high-risk … - 2024

T Hasegawa – Journal of Japanese Society of Wound, Ostomy and …, 2024 – jstage.jst.go.jp

MoistureMeterD Compact, VapoMeter

… and dermal hydration were measured using MoistureMeterD(Delphin Technologies Ltd., Kuopio, … MoistureMeterD that was used for moisture content measurement in the present study …

THE EUROPEAN JOURNAL - 2017

IINE MEDICA – Pathology, 2017 – eurolymphology.org

MoistureMeterD Compact, VapoMeter

… Therapy is conservative in most cases, and surgical for a small subset of patients. Widely used treatment methods have not yet undergone sufficient meta-analysis of multiple studies …

Poster 001

JG Thomas, E Panza – researchgate.net

MoistureMeterD Compact, VapoMeter

… Conclusions: Our findings suggest that small, but significantly more weight loss is observed in individuals with low AMY1 CNV paired with a low carb diet compared to high AMY1 CNV …

Accuracy and Precision of Multiple Laboratory and Field Methods to The Criterion In Vivo Five-Compartment Body Composition Model and Their Association with … - 2023

D Cataldi, JP Bennet, MC Wong, BK Quon, EL Young… – medRxiv, 2023 – medrxiv.org

MoistureMeterD Compact, VapoMeter

… A moisture meter(Moisture-Meter-D, Delfin Technologies) assessed tissue hydration 226 using … Due to the small sample size, we were unable to withhold a 417 subset of participants for …

Shanshan Yao

Y Zhu – mae.ncsu.edu

MoistureMeterD Compact, VapoMeter

… The AgNW hydration sensor was calibrated against a commercial hydration monitor (Moisture Meter D (MMD), Delfin Tech). As shown in Figure 3B, when the hydration level (MMD …

Arm, leg, and foot skin water in persons with diabetes mellitus (DM) in relation to HbA1c assessed by tissue dielectric constant (TDC) technology measured at 300 … - 2017

HN Mayrovitz, I Volosko, B Sarkar… – … and Technology, 2017 – journals.sagepub.com

MoistureMeterD Compact, VapoMeter

… ) was estimated by measuring TDC at a frequency of 300 MHz using the MoistureMeterD device manufactured by Delfin Technologies Ltd (Kuopio, Finland). The device (Figure 1) …

Case report in Australië

S nog geen reacties Feb – fiehuidkliniek.nl

MoistureMeterD Compact, VapoMeter

Background: Manual lymphatic drainage (MLD) is a recommend massage therapy for patients with lymphedema. The massage technique involves frictional forces between the hands of …

Oral supplementation of collagen peptides improves skin hydration by increasing the natural moisturizing factor content in the stratum corneum: a randomized, double … - 2021

M Miyanaga, T Uchiyama, A Motoyama… – Skin Pharmacology and …, 2021 – karger.com

MoistureMeterD Compact, VapoMeter

… Moisture Meter D® (Delfin Technologies, Inc., Finland). A 0.5-mm probe (XS 5) was used to measure skin water content, whereas a 1.5-mm probe (S15) was used to measure dermal …