Multiprobe MoistureMeterD publications (112)

Lymphedema (103)

Manual lymph drainage does not substantially improve the effect of decongestive lymphatic therapy in people with breast cancer related lymphoedema (EFforT … - 2023

T De Vrieze, N Gebruers, I Nevelsteen, S Fieuws… – BREAST, 2023 – lirias.kuleuven.be

MoistureMeterD Compact, Multiprobe MoistureMeterD

Questions: When added to decongestive lymphatic therapy (DLT), what is the effect of fluoroscopy-guided manual lymphatic drainage (MLD) versus traditional MLD or placebo MLD for …

Manual lymph drainage does not substantially improve the effect of decongestive lymphatic therapy in people with breast cancer related lymphoedema (EFforT … - 2023

T De Vrieze, N Gebruers, I Nevelsteen, S Fieuws… – BREAST, 2023 – lirias.kuleuven.be

MoistureMeterD Compact, Multiprobe MoistureMeterD

Questions: When added to decongestive lymphatic therapy (DLT), what is the effect of fluoroscopy-guided manual lymphatic drainage (MLD) versus traditional MLD or placebo MLD for …

Assessing non-invasive imaging devices to detect temperature differentiation and lymphatic/venous flow to the head and neck during head down tilt, supine, and … - 2023

M Melin, H Barnhart, F Aviles, J Pannunzio, N Sirkis… – 2023 – researchsquare.com

MoistureMeterD Compact, Multiprobe MoistureMeterD

… No signi cant difference for any of the within-group comparisons were found with the Lymphscanner. A signi cant reduction in left temple TDC for the treatment group was found at post-…

Diagnosis of upper quadrant lymphedema secondary to cancer: clinical practice guideline from the Oncology Section of the American Physical Therapy Association - 2017

K Levenhagen, C Davies, M Perdomo, K Ryans… – Physical …, 2017 – academic.oup.com

MoistureMeterD Compact, Multiprobe MoistureMeterD

… Additionally, 3 of the tape measurements for patients with head and neck (ear to ear; circumferential measurement of upper neck and lower neck) correlated with Moisture Meter D (MMD…

Patterns of temporal changes in tissue dielectric constant as indices of localized skin water changes in women treated for breast cancer: a pilot study - 2015

HN Mayrovitz, DN Weingrad, L Lopez – Lymphatic research and …, 2015 – liebertpub.com

MoistureMeterD Compact, Multiprobe MoistureMeterD

Background: Our goal was to characterize temporal patterns of skin Tissue Dielectric Constant (TDC) as a foundation for possible TDC use to detect and quantify lymphedema. Although …

A Prospective Preliminary Study Examining the Physiological Impact of Pneumatic Compression Dosing in the Treatment of Lower Extremity Lymphedema - 2023

V Keeley, K Riches, L Ward… – Lymphatic Research and …, 2023 – liebertpub.com

MoistureMeterD Compact, Multiprobe MoistureMeterD

… Local tissue water (LTW) was assessed by measuring tissue dielectric constant (TDC) with a Moisture Meter D (Delfin Technologies, Kuopio, Finland), at specific anatomical sites (on …

Manual lymphatic drainage with or without fluoroscopy guidance did not substantially improve the effect of decongestive lymphatic therapy in people with … - 2022

T De Vrieze, N Gebruers, I Nevelsteen, S Fieuws… – Journal of …, 2022 – Elsevier

MoistureMeterD Compact, Multiprobe MoistureMeterD

… an absolute excess volume difference, these numbers represent a range between –70 and 90 ml, which are not clinically relevant changes in the volume difference (ie, this is a small …

Use of technology to facilitate a prospective surveillance program for breast cancer-related lymphedema at the Massachusetts General Hospital - 2021

LM Havens, CL Brunelle, TC Gillespie, M Bernstein… – Mhealth, 2021 – ncbi.nlm.nih.gov

MoistureMeterD Compact, Multiprobe MoistureMeterD

… treatment and breast lymphedema, this was a small study and further research is required (22). … The MoistureMeter-D ® (Delphin Technologies) consists of a measuring unit and four …

A randomized controlled trial comparing platelet-rich plasma, low-level laser therapy, and complex decongestive physiotherapy in patients with lower limb … - 2020

A Akgul, E Tarakci, N Arman, T Civi… – Lymphatic research and …, 2020 – liebertpub.com

MoistureMeterD Compact, Multiprobe MoistureMeterD

Background: Platelet-rich plasma (PRP) is an autologous concentrated preparation of platelets characterized by lymphangiogenetic and tissue-repairing effects. Although PRP has …

Imaging of interstitial fluid in skin and subcutaneous tissue using dual-frequency ultrasonography before and immediately after lymph drainage in breast cancer … - 2013

M Dai, M Katayama, J Sugama, M Okuwa… – J Tsuruma Health Sci …, 2013 – researchgate.net

MoistureMeterD Compact, Multiprobe MoistureMeterD

… Skin moisture was measured using a Moisture Meter D (Delfin Technologies, Kuopio, … The key limitation to the present study was considered to be the small number of subjects. In …

The effect of adjuvant radiotherapy on skin biophysical properties in patients with breast cancer at risk for breast lymphedema: A prospective study - 2023

A Tuğral, M Akyol, Y Bakar – Clinical Physiology and Functional …, 2023 – Wiley Online Library

MoistureMeterD Compact, Multiprobe MoistureMeterD

… Local tissue water percentage (as measured TDC) of the ipsilateral and contralateral sites were assessed with Moisture MeterD ™ (Delfin Technologies, Kuopio, Finland) at pre-RT and …

Correlation between clinical assessment and lymphofluoroscopy in patients with breast cancer-related lymphedema: a study of concurrent validity - 2020

S Thomis, L Dams, I Fourneau, T De Vrieze… – Lymphatic Research …, 2020 – liebertpub.com

MoistureMeterD Compact, Multiprobe MoistureMeterD

… Water content A vertical pressure is performed with the MoistureMeterD Compact ® (Delfin) to … This degree of reflection/water content can be read on the display of the MoistureMeterD. …

Five-year cumulative incidence of axillary web syndrome and comparison in upper extremity movement, function, pain, and lymphedema in survivors of breast cancer … - 2022

L Koehler, A Day, D Hunter, A Blaes, T Haddad… – Archives of Physical …, 2022 – Elsevier

MoistureMeterD Compact, Multiprobe MoistureMeterD

… Technologies, b which measured local tissue water bilaterally on the trunk at a location 8 cm below the axillary fold. The MoisturemeterD … under the MoisturemeterD transducer head. …

Two-year follow-up of temporal changes of breast edema after breast cancer treatment with surgery and radiation evaluated by tissue dielectric constant (TDC) - 2015

K Johansson, MH Darkeh… – The European …, 2015 – lymphoedemaeducation.com.au

MoistureMeterD Compact, Multiprobe MoistureMeterD

… ected and contralateral sides using the MoistureMeterD (Delfin Technologies Ltd, Finland). The … This might be due to a small number of patients with ALNB and small number of patients …

The Effect of Manual Lymph Drainage and Compression Bandaging for Stage 2 Breast Cancer-Related Lymphedema: A Randomized Controlled Trial - 2023

Y Liu, X Zhao, J Song, W Zhao, Y Ge… – Lymphatic Research and …, 2023 – liebertpub.com

MoistureMeterD Compact, Multiprobe MoistureMeterD

… meter (Moisture Meter D Compact; Delfin Technologies LTD, Kuopio Finland). A probe with diameter of 23 mm and detection depth of 2.5 mm was selected in this study. Every point was …

Experimental and analytical comparisons of tissue dielectric constant (TDC) and bioimpedance spectroscopy (BIS) in assessment of early arm lymphedema in breast … - 2015

T Lahtinen, J Seppälä, T Viren… – Lymphatic research and …, 2015 – liebertpub.com

MoistureMeterD Compact, Multiprobe MoistureMeterD

… -sectional area (blood component not illustrated due to its small size), (b) in percentage the … Lahtinen has acted as a research and development manager to Delfin Technologies Ltd. …

Relation between early disturbance of lymphatic transport visualized with lymphofluoroscopy and other clinical assessment methods in patients with breast cancer - 2022

S Thomis, N Devoogdt, T De Vrieze, B Bechter-Hugl… – Clinical breast …, 2022 – Elsevier

MoistureMeterD Compact, Multiprobe MoistureMeterD

… Moisture meter D Compact (Delfin Technologies) Seven locations on the arm (Figure 3). Placement probe on the reference point with gentle pressure. PWC operated side compared to …

Role of handedness on forearm skin tissue dielectric constant (TDC) in relation to detection of early‐stage breast cancer‐related lymphedema - 2018

HN Mayrovitz, M Fasen, P Spagna… – Clinical physiology and …, 2018 – Wiley Online Library

MoistureMeterD Compact, Multiprobe MoistureMeterD

… One aspect relates to the fact that a single tissue depth was interrogated with the compact TDC device herein used. Prior reports (Mayrovitz et al., 2015a,b) have indicated that this …

Tissue dielectric constant (TDC) as an index of skin water in women with and without breast cancer: upper limb assessment via a self-contained compact … - 2016

HN Mayrovitz, DN Weingrad, L Lopez – Lymphology, 2016 – journals.uair.arizona.edu

MoistureMeterD Compact, Multiprobe MoistureMeterD

… The device used to measure TDC was the MoistureMeterD compact (MMDC) manufactured by Delfin Technologies Ltd, Kuopio, Finland. This device is a recently developed hand-held …

Reliability of the MoistureMeterD compact device and the pitting test to evaluate local tissue water in subjects with breast cancer-related lymphedema - 2020

T De Vrieze, N Gebruers, I Nevelsteen… – … research and biology, 2020 – liebertpub.com

MoistureMeterD Compact, Multiprobe MoistureMeterD

… a commercially available compact version of an open-ended coaxial probe with medium probe size 20 operating at 300 MHz, called the MMDC device (Delfin Technologies, Kuopio, …

Tissue dielectric constant combined with arm volume measurement as complementary methods in detection and assessment of breast cancer-related lymphedema - 2022

Y Liu, X Long, J Guan – Lymphatic Research and Biology, 2022 – liebertpub.com

MoistureMeterD Compact, Multiprobe MoistureMeterD

… hand was measured by using the TDC method (MoistureMeterD Compact; Delfin Technologies Ltd., Kuopio Finland). MoistureMeterD is a portable device that consists of an electronic …

Lymphatic filariasis increases tissue compressibility and extracellular fluid in lower limbs of asymptomatic young people in Central Myanmar - 2017

J Douglass, P Graves, D Lindsay, L Becker… – Tropical Medicine and …, 2017 – mdpi.com

MoistureMeterD Compact, Multiprobe MoistureMeterD

… Neither the mechanical Tonometer nor SkinFibroMeter found any clinically relevant or statistically … for all devices including the Tonometer and SkinFibroMeter are given in Table S1. …

Moderating factors in tissue tonometry and bioimpedance spectroscopy measures in the lower extremity of healthy young people in Australia and Myanmar - 2018

J Douglass, P Graves, S Gordon – Lymphatic Research and Biology, 2018 – liebertpub.com

MoistureMeterD Compact, Multiprobe MoistureMeterD

… The third device, the SkinFibroMeter, has a smaller reference plate and a fixed 1.25mm indenter. The reference plate is touched evenly to the skin five times and the average resistance …

Intrarater reliability of tonometry and bioimpedance spectroscopy to measure tissue compressibility and extracellular fluid in the legs of healthy young people in … - 2017

J Douglass, P Graves, S Gordon – Lymphatic Research and Biology, 2017 – liebertpub.com

MoistureMeterD Compact, Multiprobe MoistureMeterD

… Delfin Technologies, Finland, provided the SkinFibroMeter on loan to JCU for the purposes of the study. Delfin Technologies retain no editorial or publication rights in regard to this …

Protocol of a randomised controlled trial regarding the effectiveness of fluoroscopy-guided manual lymph drainage for the treatment of breast cancer-related … - 2018

T De Vrieze, L Vos, N Gebruers, WAA Tjalma… – European Journal of …, 2018 – Elsevier

MoistureMeterD Compact, Multiprobe MoistureMeterD

Objectives Lymphoedema is a dreadful complication following breast cancer therapy. According to the International Society of Lymphology, the consensus treatment for breast cancer-…

Does Manual Lymphatic Drainage Add Value in Reducing Suprafascial Fluid Accumulation and Skin Elasticity in Patients With Breast Cancer–Related Lymphedema? - 2022

T De Vrieze, N Gebruers, I Nevelsteen… – Physical …, 2022 – academic.oup.com

MoistureMeterD Compact, Multiprobe MoistureMeterD

… way 14 using a MoistureMeterD Compact device (Delfin Technologies, Kuopio, Finland), which … Alternatively, the SkinFibroMeter (Delfin Technologies) is a portable device that can be …

Other (9)